Implementation of locking compression plate together with intramedullary fibular graft in atrophic type humeral nonunions
Abstract
Objective This study aims to report the results of locking compression plate along with intramedullary Wbular graft that was implemented in patients with the diagnosis of nonunion of humerus diaphysis. Materials and methods Five patients, operated between 2000 and 2009 for atrophic type nonunion of humeral diaphysis, were included in this study.